Can I Order a Generator Configured for My Country?

A generator is not one product sold everywhere. Several things are decided per destination market, and none of them can be changed after the set arrives.

Reviewed by Jim Yue, Head of Supply Chain · 2026-09-17

Most of what makes a generator “right for your market” is decided before it is built, not after it lands. Frequency, voltage, socket standard, the language on the panel and the manual, and the starting aids for a cold or hot site are all destination choices. Get them wrong and the set still works, but in the wrong market.

A distributor answers this question for a whole market, not just for one customer. If you are still choosing between single-phase and three-phase for a particular site, that decision comes first. This guide covers everything that follows it.

What varies by destination, and what does not

Varies by destinationFixed when the model is chosen
Frequency: 50 Hz or 60 Hz, and the engine speed that goes with itEngine displacement and power class
Voltage configurationAlternator frame size
Socket and connector standardCooling type (air or water)
Panel, label and manual languageEnclosure type (open, silent, welding)
Cold or high-temperature starting aidsControl architecture (manual, electric start, ATS-ready)
The document set that travels with the shipment

The right-hand column is what you choose from a catalogue. The left-hand column is what you specify in the order. A supplier who only discusses the right-hand column leaves the buyer to discover the rest at the port.

50 Hz or 60 Hz changes more than the number

Frequency is not a setting. On a conventional set, it is the engine speed:

FrequencyEngine speed on our published range
50 Hz3,000 rpm (single-cylinder air-cooled) · 1,500 rpm (four-pole water-cooled)
60 Hz3,600 rpm (single-cylinder air-cooled) · 1,800 rpm (four-pole water-cooled)

Buyers often miss two consequences:

Every genset in our published range lists both a 50 Hz and a 60 Hz configuration, but a given unit is built for one of them. It is not a switch on the panel.

Voltage: read the plate, not the country

Voltage tables by country are a starting point, not an answer. Industrial sites often have a different supply from nearby homes, and older installations often differ from the national standard.

Our published sets state their voltage configuration clearly, for example 115/230 V for single-phase models and 400/230 V for three-phase ones. Compare it with the voltage measured at the site and with the nameplates on the equipment the set will run.

If a market needs a configuration outside what a model publishes, that is settled in the order, not in the catalogue; see the last section.

Sockets, panel language and the manual

These three are easy to forget and expensive to discover late:

We do not publish these three as standard specifications, because there is no single answer for a whole range. They are confirmed for each order. Ask for them clearly, in writing, before you pay a deposit.

Climate: the site decides, not the catalogue

Two conditions change what a set needs at start-up:

Cold-start aids are also confirmed for each order; they are not a catalogue item.

The one page to send your supplier

With these six lines, a competent supplier can configure the order without a second round of questions:

  1. Frequency required in the destination market: 50 Hz or 60 Hz
  2. Voltage and phase measured at the site, plus the plates of the main loads
  3. Socket or connector standard expected on the unit
  4. Language for the panel, labels and manual
  5. Climate extremes at the site: lowest temperature, highest temperature, altitude
  6. Documents your customs process requires with the shipment

For a distributor ordering for a market rather than a single site, item 2 becomes “the standard supply in the territory” and item 5 becomes “the range of conditions across the territory”. The rest of the list stays the same.

Where HTX fits

Our published range covers 2.8 to 55 kVA, with 50 Hz and 60 Hz configurations listed for every set and voltage configurations of 115/230 V and 400/230 V. The conventional sets regulate voltage with an AVR; the inverter models use an IGBT inverter instead. OEM and ODM configuration is available for distributors.

This covers a different voltage configuration, a specific socket standard, the panel and manual language, and cold-start aids. Anything beyond what a model publishes is confirmed for each order, not promised from the catalogue. Send the six lines above and we will reply in writing with what is and is not possible for that market. If the answer is no, we would rather tell you before the deposit than after.

We ship from China, and the delivery terms and price are agreed per order and depend on order volume. If you also need the calendar, how long it takes to import a diesel generator breaks the total into its four blocks.

If the order is for a public or project tender, the specification and the required documents come from the tender file. Our tender page explains what to send so we can check it line by line.


Specifying for a market rather than a single site? Send us the frequency, the standard supply voltage, the socket standard and the climate range of your territory, or message us on WhatsApp. Our engineers will confirm within 24 business hours which configurations we can supply.

Models for this job

Full specifications and a PDF spec sheet on each product page.

Need help sizing your unit?

Send us your loads, altitude and duty cycle. We will specify the right model.

Need a quote? Reply in 24 business hours