Buying Guide

Can I Order a Generator Configured for My Country?

A generator is not one product sold everywhere. Several things are decided per destination market — and none of them can be changed after the set arrives.

Most of what makes a generator “right for your market” is decided before it is built, not after it lands. Frequency, voltage, socket standard, the language on the panel and the manual, and the starting aids for a cold or hot site are all destination choices. Get them wrong and the set still works — somewhere else.

This is the question a distributor has to answer for a market, not just for one customer. If you are still deciding single-phase against three-phase for a particular site, that decision comes first; this guide is about everything that follows it.

What varies by destination, and what does not

Varies by destinationFixed when the model is chosen
Frequency — 50 Hz or 60 Hz, and the engine speed that goes with itEngine displacement and power class
Voltage configurationAlternator frame size
Socket and connector standardCooling type (air or water)
Panel, label and manual languageEnclosure type (open, silent, welding)
Cold or high-temperature starting aidsControl architecture (manual, electric start, ATS-ready)
The document set that travels with the shipment

The right-hand column is what you pick from a catalogue. The left-hand column is what you specify in the order. Suppliers who only discuss the right-hand column leave the buyer to discover the rest at the port.

50 Hz or 60 Hz changes more than the number

Frequency is not a setting. On a conventional set it is engine speed:

FrequencyEngine speed on our published range
50 Hz3,000 rpm (single-cylinder air-cooled) · 1,500 rpm (four-pole water-cooled)
60 Hz3,600 rpm (single-cylinder air-cooled) · 1,800 rpm (four-pole water-cooled)

Two consequences buyers often miss:

Every genset in our published range lists both a 50 Hz and a 60 Hz configuration, but a given unit is built for one of them. It is not a switch on the panel.

Voltage: read the plate, not the country

Country-level voltage tables are a starting point, not an answer. Industrial sites often have a different supply from nearby homes, and older installations drift from the national standard.

Our published sets state their voltage configuration explicitly — for example 115/230 V for single-phase models and 400/230 V for three-phase ones. Match that against the actual measured voltage at the site, and against the plates on the equipment the set will run.

If a market needs a configuration outside what a model publishes, that is an order-time question, not a catalogue question — see the last section.

Sockets, panel language and the manual

These three are easy to forget and expensive to discover late:

We do not publish these three as standard specifications, because they are not one fixed answer across a range — they are confirmed per order. Ask for them explicitly, in writing, before a deposit.

Climate: the site decides, not the catalogue

Two conditions change what a set needs at start-up:

Cold-start aids are again an order-time confirmation, not a catalogue item.

The one page to send your supplier

Send these six lines and a competent supplier can configure the order without a second round:

  1. Frequency required in the destination market — 50 Hz or 60 Hz
  2. Voltage and phase measured at the site, plus the plates of the main loads
  3. Socket or connector standard expected on the unit
  4. Language for the panel, labels and manual
  5. Climate extremes at the site — lowest temperature, highest temperature, altitude
  6. Documents your customs process requires with the shipment

For a distributor placing a market order rather than a single-site order, item 2 becomes “the standard supply in the territory” and item 5 becomes “the range of conditions across the territory”. The list does not change.

Where HTX fits

Our published range covers 2.8 to 55 kVA, with 50 Hz and 60 Hz configurations listed for every set, voltage configurations of 115/230 V and 400/230 V, and AVR voltage regulation throughout. OEM and ODM configuration is available for distributors.

Anything beyond what a model publishes — a different voltage configuration, a specific socket standard, panel and manual language, cold-start aids — is confirmed per order rather than promised from a catalogue. Send the six lines above and we will come back with what is and is not possible for that market, in writing. Where the answer is no, we would rather say so before a deposit than after.

Shipping is from China, CIF to your port; pricing follows order volume. If you also need the calendar, how long it takes to import a diesel generator breaks the total into its four blocks.


Specifying for a market rather than a single site? Send us the frequency, the standard supply voltage, the socket standard and the climate range of your territory — or message us on WhatsApp — and our engineers will confirm within 24 business hours which configurations we can supply for it.