Emergency & Backup Power
Standby diesel generators that take the load the moment the grid fails — for shops, clinics, farms, and homes where downtime is not an option.
- Silent sets under 75 dB for occupied areas
- Electric start — ready the moment you need it
- Sized for the loads that must not stop
The challenge
Outages never announce themselves. When the grid drops, refrigeration, tills, medical equipment, and water systems go with it — unless a standby set takes the load in seconds. The machine may wait for months, then must start on the first try. HTX standby sets are specified for exactly that duty: dependable starting, honest standby ratings, and simple monthly upkeep any operator can follow.
What a backup generator has to carry
A backup generator does not have to run everything. It has to run the loads that must not stop: refrigeration, lights, tills, computers, medical equipment and the water pump.
Fridges, freezers, pumps and air-conditioners have motors. When power returns from the generator, they all try to start at once, and each draws three times or more its running current. Size for that moment, or bring loads back one by one.
How often the grid fails also matters. Standby ratings are for occasional outages. Where power is cut for hours every day, the set is really a prime-power machine and should be sized on its prime rating.
Matching the set to the building
Typical loads. List what must keep running and use the generator size calculator to check the starts.
| Building | Typical backup load | HTX models |
|---|---|---|
| Small shop: lights, till, one fridge | 3 to 5 kVA | HTX-G6.7K-S, HTX-G7.5K-S |
| Home: lights, fridges, water pump | 5 to 8 kVA | HTX-G8.5K-S, HTX-G10K-S |
| Clinic or pharmacy: vaccine fridges, lights, computers | 8 to 12 kVA | HTX-G10K-WS, HTX-G14K-S |
| Supermarket or cold room | 15 to 30 kVA, three-phase | HTX-G19K-WS3, HTX-G31K-WS3 |
| Small hotel or office building | 30 to 55 kVA | HTX-G31K-WS3, HTX-G55K-WS3 |
| Computers and electronics only | about 3 kVA | HTX-G3K-EI |
Recommended equipment
Matched to your operation
Recommended HTX equipment for this application:
2.8kVA Open Frame Diesel Generator Set
2.8 kVA
Request Quote
4.5kVA Silent Diesel Generator Set
4.5 kVA
Request Quote
3kVA Inverter Diesel Generator Set
3 kVA
Request Quote
10kVA Single-Phase Water-Cooled Silent Diesel Generator Set
10 kVA
Request Quote
4.5kVA Open Frame Diesel Generator Set
4.5 kVA
Request Quote
5.3kVA Silent Diesel Generator Set
5.3 kVA
Request QuoteMaking sure it starts when needed
- Automatic start. An automatic transfer switch (ATS) starts the set and moves the load within seconds of an outage. It is available on our electric-start models. See what an ATS does.
- Noise. Our air-cooled silent sets measure 72 to 74 dB(A) at 7 m. Our water-cooled silent sets measure 60 to 62 dB(A) at 7 m (50 Hz), for clinics, hotels and homes.
- Monthly test. Run the set under load for about 30 minutes once a month. Check the battery each time: a flat battery is the most common reason a standby set fails to start.
- UPS. If a UPS protects your computers, the generator must be sized for the UPS input. See what size generator for a UPS.
Questions backup power buyers ask
What size backup generator does a small shop or clinic need?
List what must keep running: fridges, lights, tills, computers, medical equipment. Add their running power, then allow about three times the running power of the largest motor for its start. Many small shops need 3 to 5 kVA and many clinics 8 to 12 kVA.
Standby or prime: which rating should I compare?
Standby if outages are occasional. Prime if the grid fails for hours every day, because the set then runs like a main supply. Compare the same rating across suppliers.
Can the generator switch on automatically during a power cut?
Yes, with an automatic transfer switch. It is available on our electric-start models. It starts the set, moves the load, and switches back when the grid returns.
How quiet is a silent backup generator?
Our air-cooled silent sets measure 72 to 74 dB(A) at 7 m, and our water-cooled silent sets 60 to 62 dB(A). For comparison, an open-frame set of similar size measures 77 to 89 dB(A).